Valero Port Arthur Reports FCCU Emissions Exceedance
DAVENPORT, FL (DTN) – Valero Energy reported a particulate matter emissions exceedance involving the fluid catalytic cracking unit’s wet gas scrubber at its 360,000 bpd Port Arthur refinery in Texas, following an August stack test, according to a filing with the Texas Commission on Environmental Quality (TCEQ).
The exceedance was identified during an August 19 stack test and reported Thursday (10/15), after Valero received the final test results confirming emissions above the applicable limit.
Valero said the FCCU was temporarily operated outside normal conditions during the August test to simulate potential worst-case operating scenarios. Those atypical operating conditions inadvertently contributed to increased particulate matter emissions.
The refinery reported an estimated 61,929.45 pounds of particulate matter based on the August test results. Valero said the estimate was calculated conservatively through September 24, when a subsequent stack test produced preliminary results indicating emissions were within applicable limits.
The FCCU is a key gasoline-producing unit that converts heavier refinery streams into gasoline blendstocks and other lighter products. Its wet gas scrubber controls particulate emissions from the unit. The filing did not indicate any disruption to gasoline production.
The Port Arthur refinery primarily produces gasoline, diesel and jet fuel.
DTN reached out to Valero Energy for additional details but did not get an immediate response.
(c) Copyright 2026 DTN, LLC. All rights reserved.